TWG II-314 Brushless AC Generator (200KW-360KW)

Category:

The TWG Ⅱ series three-phase AC brushless synchronous Generator is a new generation Generator independently developed by our company based on the original TWG series, combined with advanced domestic and international brushless Generator design and manufacturing technologies. This series of Generators features compact size, light weight, exquisite appearance, and high reliability, with electrical performance reaching international advanced levels. The TWG Ⅱ series three-phase AC brushless synchronous Generator complies with IEC International Electrotechnical Commission and GB755 standards, suitable for pairing with diesel engines to form diesel Generator sets or mobile power stations, and is used in land, ships, trains, hotels, and other occasions requiring industrial frequency power supply.
  • TWG II-314 Brushless AC Generator (200KW-360KW)
  • TWG II-314 Brushless AC Generator (200KW-360KW)
  • TWG II-314 Brushless AC Generator (200KW-360KW)
  • TWG II-314 Brushless AC Generator (200KW-360KW)
  • TWG II-314 Brushless AC Generator (200KW-360KW)
TWG II-314 Brushless AC Generator (200KW-360KW)
TWG II-314 Brushless AC Generator (200KW-360KW)
TWG II-314 Brushless AC Generator (200KW-360KW)
TWG II-314 Brushless AC Generator (200KW-360KW)
TWG II-314 Brushless AC Generator (200KW-360KW)
+

Specifications


MAIN PERFORMANCE INDEX:

01.Drip-leak-proof structure:(lP22 protection class)   
02.Instulation class H   
03.Rated voltage 400V   
04.Three phase four threads   
05.Adjusting rate of stable voltage≤ ±1%   
06.Transient state voltage≤-15%~+20%   
07.Wave aberration rate of voltage THD≤3%   
08.Telephone harmony wave factor of thlephone THF≤2%   
09.Telephone eff.ective factor of telephone TIF≤50   
10.Voltage of other range depends on the costumers request

 

ENVIRONMENT CONDITIONS:

Under the following environment, the generator could running continuously:  
1.Altitude: not exceed 1000m  
2.Cooling air temperature: 258~313k (-15°C-40°C)  
3.Relative air humidity: not exceed 90%

 

Correction Factor:

Altitude(m)

Cooling air temperature (℃)

<3030~4040~4545~5050~5555~60
< 10001.041.000.970.940.900.85
1000~15001.010.970.940.910.870.82
1500~20000.980.940.910.880.840.79
2000~25000.940.900.870.840.800.75
2500~30000.900.860.830.800.760.71
3000~35000.860.820.790.750.710.66
3500~40000.810.770.740.700.660.61
>4000As requiredAs requiredAs requiredAs requiredAs requiredAs required

According to customer requirements

 

FEATURES:

1.Reliable AVR exciting system and optional permanent magnetic system always provide in variable excitation on all occasions

2.Easy to be connected with power network of parallel other genera tors  
3.Balanced rotor, sealed single and double ball bearings

4.Convenient installation and easy maintenance, easy access to terminal. Rotating rectifier and coupling bolts

5.Wide range of flange adapter and coupling disc for single bearing

6.In conformity with all mainland standard

 

ELECTRICAL CHARACTER:

The standard AVR include Sx440, SX460、 KRS440B、 MX341B OR MX321 (optional AVR) 
The main stator provides the exciter stator with the power via AVR. The high efficiency semiconductor inside AVR ensures the output voltage gradually up to the rated value from the initial lower remanence voltage. The power of the exciters rotor is output to the host rotor through 3-phasefullwave rectifier. Two ends of the rectifier are connected with piezo resistance for restraining surge voltage and avoiding the impact caused by short circuit of parallel synchronization loss. Exciters stator is equipped with permanent magnetic steel can make generator starting smoothly in any occasions. Whole stable voltage regulation is 1%, and SX440, KRS440B、 MX341B、 MX321 have features of parallel connection. Low frequency protection and exterior voltage adjustment, etc. 
MX341B and MX321 are the AVR for the permanent magnetic motors. 

 

VOLTAGE REGULATION: 

Voltage regulation refers to the change of voltage from non-load to full-load with power factor langing from 0.8 to 1 and 4%'s fuctuation of the speed of engine. Voltage is adjusted via potention meter of AVR.

 

ELECTRIC FEATURES:

INSULATION:

Insulation class H

All regulatory components are made up with special materials and also immersed in lacquer by peculiar tech. Varnish and colophony materials are developed to strengthen the processing and machinery intensity of windings and revoving parts for protecting the generator work under corrosive environment.

 

WINDINGS AND ELECTRIC FEATURES:

All the generator stators adopt high magnetic conductibility energy cold rolling silicon steel plate to fold up, double winding,firm structure, good insulating.Continuous damp windings abate surges. T'he poles and teeth of the windings are carefully chosen, which helps checking the wave distortion of output voltage. 

 

PHONE INTERFERENCE:

THF (as defined by BS EN 600 34-1) <2%.TIF (as defined by NEMA MG1-22) <50.

 

RADIO INTERFERENCE:

Brushless apparatus and high quality AVR ensure little radio interference in transmission.RFI noise filter is also available.

 

MECHANIC FEATURES:

FRAME:

All the industrial generator's standard is IP22 (GB/T 4942.1, IEC 60034-5) .IP23 is also available, but rated power will decrease 5%.Marinegenerator is IP23 as normal standard. Air filter is an option, but rated power will decrease 5% while it is installed. 

 

AXIS AND KEY:

All rotors should pass balance test, which vibration is lower than the minimum value of BS6861 P.1,G2.5.Two-bearing generator has a half-key testing balance. 

 

TERMINAL AND TERMINAL BOX: 

The normal three-phase generators have 12 leads brought out to the terminals in the terminal box.The terminals are put on the board of the non-drive end. AVR is mounted in the terminal box made in steel sheet and enough space left inside for laying wires. The box is equipped with removable panels. 

 

ENGINE ADAPTOR AND COUPLING:

TwG series generators have two kinds of structure, single bearing and double bearing. 
Engine adapler for single-beaing could be SAE00、0、 12、 1, 2、3、 4 and 5, Couping disc for single-beaing could be SAE#6.5, 7.5, 8.10,,11.5, 14, 16, 18and 21. 
Engine adapter for double-bearing could be SAE#00, 0, 1/2, 1, 2, 3, 4 and 5.

 

OPTION FEATURES:

1.Adapters and interchangeable drive disk 
2.Single phase 
3.Remote voltage adjust 
4.IP23 protection class 
5.Space heaters 
6.Thermistors 
7.Circuit breaker

TYPE AND CAPACITY

TYPERated Power (4P-1500rpm 2P-3000rpm 50HZ 400V)Weight(kg)
Continuous/40°CStand by/40°CStand by/27°C
H 125KH 150KH 163KSingle BearingDouble Bearing
kVAkWη(%)kVAkWkVAkW
TWG II 162D12.51073.213.81115128389
TWG II 162E151276.816.513.21814.594100
TWG II 162F17.51478.919.515.62116.8101107
TWG II 162G252081.227.5223024117123
TWG II 182H302481.632.5263528130136
TWG II 182J352882.537.5304032143149
TWG II 182K37.53084.5403242.534159165
TWG II 164A7.5678.58.16.58.66.98288
TWG II 164B10878.810.88.611.59.28692
TWG II 164C12.51080.613.510.814.411.59298
TWG II 164D151281.216.31317.313.895101
TWG II 184E201684.521.617.32318.4116122
TWG II 184EC22.5188524.319.425.920.7125131
TWG II 184F252085.92721.628.823146152
TWG II 184FC27.5228629.823.831.625.3148154
TWG II 184G302486.332.425.934.527.6150156
TWG II 184GC352886.437.129.738.931.1160166
TWG II 184H37.53086.6403241.333182188
TWG II 184J42.53486.8453647.538193199
TWG II 224BC37.53086.7403241.333215221
TWG II 224B42.53487453647.538235241
TWG II 224C50408852.5425544252258
TWG II 224DC56.34588.4604862.550268274
TWG II 224D604888.66350.56653278284
TWG II 224E72.5589077.5628064300306
TWG II 224FC806490.185688870.5320326
TWG II 224F856890.290729475340346
TWG II 224G947590.31008010685350356
TWG II 274B1008090.41068511088360366
TWG II 274C117.59490.8127.5102131105385391
TWG II 274CC12510091132.5106137.5110419425
TWG II 274D14011291.5147117.6154123430436
TWG II 274EC15012092.1160128165132455461
TWG II 274E16012892.3170136176141475481
TWG II 274FB17514092.4185148194155504510
TWG II 274F18114592.4190152200160520526
TWG II 274FC19015292.5200160212.5170540546
TWG II 274G20016093.3212.5170220176570576
TWG II 274H22518093.1237.5190250200590596
TWG II 274HC25020093270216275220610616

 

TYPERated Power ( 4P-1500rpm 2P-3000rpm 50HZ 400V )Weight(kg)
Continuous∕40°CStand by∕40℃Stand by∕27℃
H 125KH 150KH 163KSingle BearingDouble Bearing
kVAkWη(%)kVAkWkVAkW
TWG II 314BC25020092.2270216275220790795
TWG II 314B27522092.4289231305244815820
TWG II 314C30024092.7320256330264860865
TWG II 314DB31225093.1331265344275920925
TWG II 314DC32526093.1345276362.5290930935
TWG II 314D35028093.3370296388310940945
TWG II 314EC37530093.440032041933510501055
TWG II 314E40032093.542534045036010651070
TWG II 314F4503609447838249539611251130
TWG Il 354B45036094.147838249539611601170
TWG II 354C50040094.452542055044012701280
TWG II 354CC562.545094.5587.547062550013001310
TWG II 354D60048094.664051266553214101420
TWG Il 354DC62550094.6662.5530687.555014281438
TWG II 354EC66253094.869555673158515101520
TWG Il 354E70056094.8737.559077061615631573
TWG II 354F75060093.377562079063216831693
TWG Il 404B75060093.377562079063217801780
TWG II 404C80064093.682566084067218201820
TWG II 404D90072093.8937.5750957.576618901890
TWG Il 404E100080094.31030824105084020002000
TWG II 404F112590094.71162.59301187.595022502250
TWG Il 404G12501000951287.510301312.5105025402540
TWG II 404H1400112095146011681500120027002700
TWG Il 454B1400112095.2146011681500120026772677
TWG II 454C1550124095.6161512921660132828802880
TWG II 454D1688135095.9175014001800144031003100
TWG Il 454E1875150096.1195015602000160032003200
TWG II 454F2000160096.2210016802150172036003600
TWG II 454G2250180095.8233018642400192038503850
TWG II 454H2500200095.7260020802670213643004300

REMARK:

*All the rated are on basis of environment temperature 40'C,altitude not exceeding 1000m.

*Diferent temperature ofers diferent standby power,the dehne of the standby power is related to the standard of lSo528-3

*The dripproof shutter plate on air outlet of motor is standard conhguration for marine type.And non-marine use on reguest.

*Other pole generator,please contact the vanufacture.

*Other power and voltage generator are on user request.

*Allextended models of generator installation dimensions in order to shape the frst letter of core length of the code shall preva.Eq.TWGII274ECdimensions are same to TWG ll 274E.

 

TYPERated Power (4P-1800rpm 2P-3600rpm 60HZ 480V )Weight(kg)
Continuous/40°CStand by∕40℃Stand by∕27℃
H 125KH 150KH 163KSingle BearingDouble Bearing
kVAkWη(%)kVAkWkVAkW
TWG II 162D15.612.571.916.913.517.5148389
TWG II 162E18.81575.8201622.51894100
TWG II 162F21.917.578.123.218.52621I01107
TWG II 162G31.32580.634.427.537.530117123
TWG II 182H352880.937.5304032130136
TWG II 182 J403282.142.5344536143149
TWG II 182K46.937.584504052.542159165
TWG II 164A9.47.578.510810.58.48288
TWG II 164B12.5107913.81114.511.58692
TWG II 164C15.612.580.316.913.517.5149298
TWG II 164D18.81581.2201621.251795101
TWG II 184E252083.826.821.428.823116122
TWG II 184EC27.52283.830243226125131
TWG II 184F31.32585.533.526.836.229146152
TWG II 184FC32.52685.635283830148154
TWG II 184G37.53086.739.431.54133150156
TWG II 184GC43.83586.846.837.548.839160166
TWG II 184H47.53885.6504052.542182188
TWG II 184J52.54286.5564558.847193199
TWG Il 224BC47.53887.552.54256.345215221
TWG Il 224B52.54287.758.146.562.550235241
TWG II 224C655288.6705672.558252258
TWG Il 224DC705689.275608064268274
1WG II 224D756089.380648568278284
TWG II 224E87.57090.5957610080300306
TWG II 224FC957690.61008010584320326
TWG II 224F102.58290.811088112.590340346
TWG Il 224G112.5909112096125100350356
TWG Il 274B125I0091132.5106137.5110360366
TWG Il 274C14511691.2155124160128385391
TWG Il 274CC15012091.3160128165132419425
TWG II 274D17013691.5177.5142187.5150430436
TWG Il 274EC18014492.1190152200160455461
TWG II 274E19015292.3200160210168475481
TWG II 274FB212.517092.6223178234187504510
TWG Il 274F22017692.6230184245196520526
TWG II 274FC22518092.7237.5190250200540546
TWG Il 274G24519693.5255204275220570576
TWG Il 274H27522093.6287.5230300240590596
TWG Il 274HC30024092.5315252330264610616

 

TYPERated Power ( 4P-1800rpm 2P-3600rpm 60HZ 480V )Weight(kg)
Continuous∕40°CStand by∕40℃Stand by∕27℃
H 125KH 150KH 163KSingle BearingDouble Bearing
kVAkWη(%)kVAkWkVAkW
TWG II 314BC30024092.5315252330264790795
TWG II 314B31525292.8335268345276815820
TWG Il 314C37530093.3400320415332860865
TWG II 314DB38530893.4405324423339920925
TWG II 314DC39331593.4415332430344930935
TWG Il 314D42534093.5450360475380940945
TWG II 314EC44035293.646036850040010501055
TWG II 314E47538093.650040052542010651070
TWG Il 314F55044094.258246660648511251130
TWG II 354B56245094.259647761849511601170
TWG Il 354C62550094.666052869055212701280
TWG II 354CC69055294.772558076060813001310
TWG II 354D74559694.880064082566014101420
TWG Il 354DC77562094.882566085068014281438
TWG II 354EC8126509585468389471515101520
TWG II 354E8506809590072094075215631573
TWG Il 354F89571693.6928.8743938.875116831693
TWG II 404B89571693.6928.8743938.875117801780
TWG II 404C957.576693.8992.5794100080018201820
TWG Il 404D108887094.51125900113891018901890
TWG II 404E120096094.812359881250100020002000
TWG Il 404F1325106095.1135610851388111022502250
TWG II 404G1450116095.5150012001550124025402540
TWG Il 404H1624130095.5168113451737139027002700
TWG II 454B1690135295.5176014081810144826772677
TWG Il 454C1890151295.7197015762025162028802880
TWG II 454D2050164096.1214017122200176031003100
TWG II 454E2250180096.1235018802425194032003200
TWG Il 454F2500200096.3262521002700216036003600
TWG II 454G2800224096.1290023203000240038503850
TWG Il 454H3100248096320025603300264043004300

REMARK:    
*All the rated are on basis of environment temperature 40'c,altitude not exceeding 1000m.

*Different temperature offers different stand by power, the Defne of the standby power is related to the standard of 1So528-3

*The drip proof shutter plate on air outlet of motor is standard conjuration for marine type. And non-marine use on request.

*Other pole generator, please contact the Manufacture,*Other power and voltage generator are on user request.

*All extended models of generator installation dimensions in order to shape the first letter of core length of the code shall preval.Eg,.TWGl!274ECdimensions are same to TWG ll 274E.

OUTLINEFORTWGII314B-F(SINGLE BEARING)

DIMENSION

MODELABCD
TWG II 314B11721101584493
TWG II 314C11721101584493
TWG II 314D11721101584493
TWG II 314E12621191674583
TWG II 314F12621191674583

FLANGE

SAE.No.RSTWXU
01614679.5647.671111.25
1/21214619.1584.168015
11212.7530.2511.161715
21211466.7447.661715
31211428.6409.561715

DISC COUPLING

SAE.No.ANARASATV
11.539.6811.5333.4352.3
1425.4813.5438.2466.5
1815.7616.7542.9571.1

 

OUTLINE FOR TWG II 314B2-F2(DOUBLE BEARING)

DIMENSION

MODELABCD
TWG II 314B213261255554463
TWG II 314C213261255554463
TWG II 314D213261255554463
TWG II 314E214161345654553
TWG II 314F214161345654553

Key words:

Electric motor

Generator

brushless AC generator

Related Products

Product Inquiry

* Note: Please be sure to fill in the information accurately and keep communication smooth. We will contact you as soon as possible.